Casella CEL-35X dBadge Users Handbook – Page 24
Display
Setup
Blue LED
Off
Blue LED
Flashing Slow
Blue LED
Flashing Fast
ISO
Leq <=79.9dB(A)
AND
Lpk <=134.9dB(C)
Leq >=80 & <=84.9
dB(A)
OR
Lpk >=135 & <=136.9
dB(C )
Leq >=85dB(A)
OR
Lpk >=137dB(C)
OSHA
Lavg (T=80)
<=84.9dB(A)
AND
Lpk <=139.9dB(Z)
Lavg (T=80) >=85 (A)
OR
Lpk >=140dB(Z)
Lavg (T=80)
>=85dB(A)
AND
Lpk >=140dB(Z)
For the ISO mode, the alarm levels are based upon the EU
directive 2003/10/EC. OSHA levels are based upon the American
Occupational Safety and Health Administration (OSHA)
regulations. As an example, if the CEL-35X is in ISO mode, and
the Leq rises above 80dB(A) then the LED will flash slowly (approx
once per second). If an impulsive noise occurs above 137dB(C)
peak, the blue LED will flash quickly (approximately twice per
second). Note that for peak levels the action level only needs to
be exceeded once during the day for the employee to be over the
relevant action level. However, for the time-averaged data (Leq
and Lavg) the LED may switch on and off depending on how the
employees’ exposure varies throughout the day. It is important to
realise alarm indications are based on the average or peak levels
since the start of the run, and not averaged to 8 hours.